Sample temperature range -55~85 ℃ (supports non-standard customization)
temperature uniformity - ±2℃
Sample temperature uniformity - ±4℃
light source driver -EPS
Light source category - Metal halide lamp
light source power - 2kv
Lamp quality assurance -1500h
spectral range -280-320nm 320-400nm
service life - ≥2500h
UVB/(UVA+UVB) -3%~10%
Light intensity range - ≤ 250W/m ² (can be upgraded to a maximum of 900Wm?)
non-uniformity - ≤±10%
Customized functions
cooling method -- air cooling
Test purpose: Prior to the thermal cycling/wet freezing test, the photovoltaic modules are pre treated with ultraviolet (UV) radiation to evaluate the UV resistance of materials and adhesives that are easily degraded by UV radiation.Test purpose:
Prior to the thermal cycling/wet freezing test, the photovoltaic modules are pre treated with ultraviolet (UV) radiation to evaluate the UV resistance of materials and adhesives that are easily degraded by UV radiation.
customized service
-XY axis uniformity scanning system - multiple UV testing