IEC 60243 Power Frequency Test for Electrical Strength of Solid Insulating Materials
Scope of application:
It is mainly suitable for continuous and uniform step-by-step step-up, applying AC/DC voltage to the specimen until breakdown, measuring the breakdown voltage value, and calculating the breakdown strength of the sample; Use the method of rapid voltage increase to raise the voltage to the specified value, keep the sample without breakdown for a certain time, and set the specified value at this time as the withstand voltage value of the sample.
Technical Requirements:
1. Test voltage: AC 0~100 kV continuously adjustable DC 0~100 kV continuously adjustable;
2. Transformer capacity: 20 KVA;
3. Breakdown voltage: 10 kV ~100kV;
4. Input voltage: AC 220V;
5. Output voltage: AC 0--100 KV;
6. High voltage classification: 0-5KV, 0-10KV, 0-20KV, 0-50KV;
7. Boost rate: 10-5000 V/S (different boost rate can be set according to user needs);
8. Test method:
DC test: 1, constant speed boost 2, gradient boost 3, withstand voltage test;
AC test: 1. Constant speed boost 2. Gradient boost 3. Withstand voltage test;
9. Voltage accuracy: ≤1%;
10. Install an overcurrent protection device with high sensitivity to ensure that the power supply is cut off within 0.1S when the sample breaks down;
11. Adopt advanced non-contact element constant speed pressure regulation mode;
12. Support the requirements of short circuit test in a short time;
13. Electrode specifications: ¢25mm two sheet electrodes ¢75mm one (can be produced according to customer needs);
14. Main machine size: L 1500× W 900×H 1700 mm;
15. Size of operating table: 400×400×520mm;
16. Protective cover material: acrylic material like crystal;
17. Power supply: AC 220V ±10%, 50Hz±1;
18. Rated power: 5KVA;
19. Weight: 220KG;
Standards:
Comply with GB/T 1408.1-2016 "Insulating materials -- Test methods for electrical strength – Part 1 – Test under power frequency";
IEC60243-1:2013 "Test Method for Electrical Strength of Solid Insulating Materials—Test under Power Frequency";
IEC60243-2 Test standard requirements of "Test Method for Electrical Strength of Solid Insulating Materials - Corresponding DC Voltage Test".
Our services:
1. High quality assurance.
2. Shipment of professional documents.
3. Packed according to your requirements, photos are attached before shipment.
4. Reply within 48 hours, 3 working days
5. Professional after-sales service of our engineers.
6. Warranty period is 12 months.
Our advantages:
1. Professional technical support.
2. Rich experience in loading a large number of containers in Chinese seaports.
3. Fast shipping by well-known shipping company.
4. Best service with email after shipment.
5. We are a professional testing equipment manufacturer in China, with rich experience and skills, and also with the best quality products.
6. Timely after-sales service