Gypsum Board In Burning Stability Tester For The Gyp Sum Board With Fire State Of Thermal Stability

1 conjunto
MOQ
US$2000-$30000
preço
Gypsum Board In Burning Stability Tester For The Gyp Sum Board With Fire State Of Thermal Stability
Características Galeria Descrição de produto Converse agora
Características
Especificações
Porto de exaustão: Alterado de retangular para circular, com um diâmetro de 406 mm
Termopar: diâmetro 3mm, 3 peças, ômega
Faixa de medição: ≥1300℃
Medição da densidade de fumaça: Instalado a uma distância de 4,9 a 12,2 metros do forno do túnel
Precisão da medição de tensão: ≤ 5%
Sistema de ignição: ignição eletrónica de alta tensão
Tensão: AC380V±10%
Temperatura refratária de tijolos: 2500 ℃
Fornos de túnel: 7,62m de comprimento
Destacar:

gypsum board fire stability tester

,

thermal stability testing equipment

,

construction material fire resistance tester

Informação básica
Lugar de origem: CHINA
Marca: CHENGFENG
Certificação: ISO,CE
Número do modelo: CF8419
Condições de Pagamento e Envio
Detalhes da embalagem: caixas de madeira
Tempo de entrega: 10 dias de trabalho
Termos de pagamento: T/T, Cash, L/C, Western Union, MoneyGram
Habilidade da fonte: 1 unidade por mês
Descrição de produto

Basic Introduction
It is mainly applicable to the determination of the surface combustion characteristics of building materials and the flame spread rate of exposed surfaces such as walls, ceilings (including solid plastics), and at the same time to measure smoke density. This testing method is applicable to exposed ceilings or walls, provided materials or general assemblies, with their own structural quality or testing aspects and aimed at using positions or support periods that can support themselves. This method determines the corresponding combustion behavior of the material by observing the spread of the flame along the sample. The development of flame spread and smoke density was reported, but this is not necessarily the relationship between the two measurements.

 

Meet the standards
ASTM E84: Standard test method for burning characteristics of building materials surfaces;
UL723: Test Standard Requirements for Surface Burning Characteristics of Building Materials;

 

Grade classification
ASTM E84 Class A requirements: 0 < FSI value ≤25 and smoke index < 450
ASTM E84 Class B requirements: 26≤FSI value ≤75 and smoke index < 450
ASTM E84 Class C requirements: 76≤FSI value ≤200 and smoke index < 450
ASMT E84 test sample requirements: 7320mm×530mm× thickness

 

Combustion system
1. 10kV spark igniter, equipped with a safety ceasefire device. The igniter is automatically positioned through a lever connected to the shut-off mechanism:
2. The combustion heat of the burner is automatically controlled by the automatic gas flow control system. The reading accuracy is 1%
3. Bipolar gas flow valve control system: To prevent gas leakage in the system caused by solenoid valve failure, thereby avoiding explosion risks
4. The variable frequency fan automatically controls the wind speed in the flue: Fan power 3KW, voltage 380V
5. Taiwanese brand gas pressure gauges and pressure regulating valves precisely control gas pressure
6. Brand gas flow control valve, precisely controlling gas flow

Produtos recomendados
Entre em contato conosco
Pessoa de Contato : Mia Feng
Telefone : +86-13128029450
Caracteres restantes(20/3000)