It is used for tensile tests of insulation sheaths of polymer materials, wires and cables, rubber, plastics, etc. in low-temperature environments, in compliance with standards: This device complies with test standards such as GB/T 2951.4, VDE 0472Part616, and IEC60811-1-4. It is suitable for wire and cable testing centers, inspection stations, wire and cable manufacturers, and research institutions for polymer materials.
Maximum stretching length: 280mm
Stretching speed: 20-30mm/ min. Chuck type: Non-self-tightening
Sample specification: 1. No. 1 dumbbell sheet;
Displacement measurement: Digital display
Elongation accuracy: ± 1%
Resolution: 0.1%
Temperature range: RT to -25℃
Tensile force range: 0 to 50kg
Tensile force accuracy: 0.01kg Unit conversion: kg/N/Lb
Refrigeration method: Air refrigeration is adopted.
DX8404 Lemon Gum Tester
Test method: First, set the micrometer to zero (you can turn the black circle outside the micrometer to set it to zero), and then press the machine by hand
"Handle