The wire winding and adhesion test device complies with the GB4909.7-85 standard "Test Methods for Bare Wires - Winding Test"
Check the occasion.
Requirements for wire winding and adhesion test device winding test:
Sample diameter: Aluminum wire Φ1.25-Φ6.00mm, steel wire Φ1.25-Φ3.80mm
Mandrel diameter: Φ1.25-Φ19.00mm
Spindle speed: ≤8r/min
4. Displacement distance of the right shaft head: ≥40
Overall speed ratio: 173.75
Motor: Power 0.75KW
Rotational speed: 1500 r/min
External dimensions: 810mm×400mm × 1400mm
Coating adhesion test: One 250ml glass graduated cylinder, one 3x magnifying glass and one 7x magnifying glass