仕様
出力電圧AC: 0.5kV~6.0kV
容量: 通常 ≥ 1.5 kVA
電圧測定精度: ±2%
電極材料: プラチナまたはステンレススチール
電極圧力: 1.0N±0.05N
解像度を落とす: 1滴あたり0.01~0.1mL(調整可能)
テスト期間の範囲: 0~9999分
作業環境温度: 0~40℃、湿度:<85%
ハイライト:

Solid insulation material tester

,

Electrical dielectric strength tester

,

Rubber insulation testing equipment

基本情報
起源の場所: 中国
ブランド名: CHENGFENG
証明: ISO,CE
モデル番号: CF8428
お支払配送条件
パッケージの詳細: 木製ケース
受渡し時間: 10営業日
支払条件: T/T、Cash.L/C、D/A、D/P、ウェスタンユニオン、マネーグラム
供給の能力: 1か月あたり5ユニット
製品の説明

During the test, two specific electrodes are placed on a flat sample surface at a specified pressure (such as 1N). Apply a high-voltage alternating current (such as 2.5kV, 4.0kV, 6.0kV, etc.) between the electrodes. Meanwhile, a specified concentration of electrolyte (usually ammonium chloride solution) is dropped onto the surface of the sample between the electrodes at constant time intervals (such as 30 seconds) through a droplet device.
Under the combined effect of high pressure and contaminated liquid, leakage current will occur on the surface of the sample and may trigger small electric sparks. If the material is not resistant, these electric sparks will gradually carbonize its surface, forming dendritic conductive channels, which are known as "electric marks". The equipment will continuously monitor the circuit current. Once the current exceeds the set threshold and remains at this level for a sufficient period of time, the equipment will automatically determine that the sample has failed (electrical tracking has occurred), cut off the high voltage, and record the test time or the voltage value it can withstand.

The main standards followed
The equipment of Dongguan Daxian strictly adheres to the following international and national standards:
IEC 60587: "Test methods for Resistance to tracking and erosion of Electrical insulating Materials Used in Harsh Environmental Conditions" - This is the core standard for high-voltage tracking tests.
GB/T 6553: "Determination of resistance to tracking and erosion of Electrical insulating materials used in Harsh Environmental Conditions" (equivalent to IEC 60587).
ASTM D2303: "Test method for tracking Resistance of Solid Electrical Insulating Materials in Moist Conditions"
And other relevant industry standards, such as JB/T, DL standards, etc.

Project parameter description
Output voltage AC: 0.5 kV to 6.0 kV (continuously adjustable, or higher)
The capacity is usually ≥ 1.5 kVA
The voltage measurement accuracy is ±2%
Electrode material: platinum or stainless steel (conforming to standard dimensions)
Electrode pressure: 1.0 N ± 0.05 N (Standard configuration)
The drip interval is adjustable from 10 to 99.9 seconds, with an accuracy of ±1%
Drop resolution: 0.01-0.1 mL per drop (adjustable)
The current determination threshold is available in multiple Settings (such as 10, 20, 30, 40, 50, 60mA), and the holding time can be set (such as 2 seconds).
The test duration ranges from 0 to 9999 minutes (adjustable, and will automatically stop upon arrival).
Working environment temperature: 0-40℃, humidity: < 85%