제품 사양
출력 전압 AC: 0.5kV ~ 6.0kV
용량: 일반적으로 ≥ 1.5kVA
전압 측정 정확도: ± 2%
전극 재료: 백금 또는 스테인리스 스틸
전극 압력: 1.0N±0.05N
해상도 저하: 한 방울당 0.01-0.1mL(조정 가능)
테스트 기간 범위: 0~9999분
작업 환경 온도: 0-40℃, 습도: < 85%
강조하다:

Solid insulation material tester

,

Electrical dielectric strength tester

,

Rubber insulation testing equipment

기본 정보
원래 장소: 중국
브랜드 이름: CHENGFENG
인증: ISO,CE
모델 번호: CF8428
결제 및 배송 조건
포장 세부 사항: 나무 케이스
배달 시간: 근무일 기준 10일
지불 조건: T/T, Cash.L/C, D/A, D/P, 서부 동맹, MoneyGram
공급 능력: 한 달에 5 단위
제품 설명

During the test, two specific electrodes are placed on a flat sample surface at a specified pressure (such as 1N). Apply a high-voltage alternating current (such as 2.5kV, 4.0kV, 6.0kV, etc.) between the electrodes. Meanwhile, a specified concentration of electrolyte (usually ammonium chloride solution) is dropped onto the surface of the sample between the electrodes at constant time intervals (such as 30 seconds) through a droplet device.
Under the combined effect of high pressure and contaminated liquid, leakage current will occur on the surface of the sample and may trigger small electric sparks. If the material is not resistant, these electric sparks will gradually carbonize its surface, forming dendritic conductive channels, which are known as "electric marks". The equipment will continuously monitor the circuit current. Once the current exceeds the set threshold and remains at this level for a sufficient period of time, the equipment will automatically determine that the sample has failed (electrical tracking has occurred), cut off the high voltage, and record the test time or the voltage value it can withstand.

The main standards followed
The equipment of Dongguan Daxian strictly adheres to the following international and national standards:
IEC 60587: "Test methods for Resistance to tracking and erosion of Electrical insulating Materials Used in Harsh Environmental Conditions" - This is the core standard for high-voltage tracking tests.
GB/T 6553: "Determination of resistance to tracking and erosion of Electrical insulating materials used in Harsh Environmental Conditions" (equivalent to IEC 60587).
ASTM D2303: "Test method for tracking Resistance of Solid Electrical Insulating Materials in Moist Conditions"
And other relevant industry standards, such as JB/T, DL standards, etc.

Project parameter description
Output voltage AC: 0.5 kV to 6.0 kV (continuously adjustable, or higher)
The capacity is usually ≥ 1.5 kVA
The voltage measurement accuracy is ±2%
Electrode material: platinum or stainless steel (conforming to standard dimensions)
Electrode pressure: 1.0 N ± 0.05 N (Standard configuration)
The drip interval is adjustable from 10 to 99.9 seconds, with an accuracy of ±1%
Drop resolution: 0.01-0.1 mL per drop (adjustable)
The current determination threshold is available in multiple Settings (such as 10, 20, 30, 40, 50, 60mA), and the holding time can be set (such as 2 seconds).
The test duration ranges from 0 to 9999 minutes (adjustable, and will automatically stop upon arrival).
Working environment temperature: 0-40℃, humidity: < 85%