Rubber Testing Equipment Featuring High Voltage Application and Electrolyte Droplet Method for Surface Resistance Testing

1 комплект
MOQ
US$2000-$30000
цена
Rubber Testing Equipment Featuring High Voltage Application and Electrolyte Droplet Method for Surface Resistance Testing
Характеристики Галерея Характер продукции Побеседуйте теперь
Характеристики
Характеристики
Выходное напряжение переменного тока: от 0,5 кВ до 6,0 кВ
Мощность: обычно ≥ 1,5 кВА
Точность измерения напряжения: ± 2%
Электродный материал: Платина или нержавеющая сталь
Давление электрода: 1,0 Н ± 0,05 Н
Удалить разрешение: 0,01–0,1 мл на каплю (регулируется)
Диапазон продолжительности испытаний: от 0 до 9999 минут
Рабочая среда температура: 0-40℃, влажность: <85%
Выделить:

Solid insulation material tester

,

Electrical dielectric strength tester

,

Rubber insulation testing equipment

Основная информация
Место происхождения: Китай
Фирменное наименование: CHENGFENG
Сертификация: ISO,CE
Номер модели: CF8428
Оплата и доставка Условия
Упаковывая детали: Деревянные ящики
Время доставки: 10 рабочих дней
Условия оплаты: Т/Т, наличные.Л/К, Д/А, Д/П, западное соединение, МонейГрам
Поставка способности: 5 единиц в месяц
Характер продукции

During the test, two specific electrodes are placed on a flat sample surface at a specified pressure (such as 1N). Apply a high-voltage alternating current (such as 2.5kV, 4.0kV, 6.0kV, etc.) between the electrodes. Meanwhile, a specified concentration of electrolyte (usually ammonium chloride solution) is dropped onto the surface of the sample between the electrodes at constant time intervals (such as 30 seconds) through a droplet device.
Under the combined effect of high pressure and contaminated liquid, leakage current will occur on the surface of the sample and may trigger small electric sparks. If the material is not resistant, these electric sparks will gradually carbonize its surface, forming dendritic conductive channels, which are known as "electric marks". The equipment will continuously monitor the circuit current. Once the current exceeds the set threshold and remains at this level for a sufficient period of time, the equipment will automatically determine that the sample has failed (electrical tracking has occurred), cut off the high voltage, and record the test time or the voltage value it can withstand.

The main standards followed
The equipment of Dongguan Daxian strictly adheres to the following international and national standards:
IEC 60587: "Test methods for Resistance to tracking and erosion of Electrical insulating Materials Used in Harsh Environmental Conditions" - This is the core standard for high-voltage tracking tests.
GB/T 6553: "Determination of resistance to tracking and erosion of Electrical insulating materials used in Harsh Environmental Conditions" (equivalent to IEC 60587).
ASTM D2303: "Test method for tracking Resistance of Solid Electrical Insulating Materials in Moist Conditions"
And other relevant industry standards, such as JB/T, DL standards, etc.

Project parameter description
Output voltage AC: 0.5 kV to 6.0 kV (continuously adjustable, or higher)
The capacity is usually ≥ 1.5 kVA
The voltage measurement accuracy is ±2%
Electrode material: platinum or stainless steel (conforming to standard dimensions)
Electrode pressure: 1.0 N ± 0.05 N (Standard configuration)
The drip interval is adjustable from 10 to 99.9 seconds, with an accuracy of ±1%
Drop resolution: 0.01-0.1 mL per drop (adjustable)
The current determination threshold is available in multiple Settings (such as 10, 20, 30, 40, 50, 60mA), and the holding time can be set (such as 2 seconds).
The test duration ranges from 0 to 9999 minutes (adjustable, and will automatically stop upon arrival).
Working environment temperature: 0-40℃, humidity: < 85%