| Warranty | 1 Year |
|---|---|
| Customized Support | OEM, ODM, OBM, Software Reengineering |
| Place Of Origin | Guangdong, China |
| Brand Name | CHENGFENG |
| Model Number | CF8364 |
| Warranty | 1 Year |
|---|---|
| Model Number | CF8342 |
| Power | Electronic |
| Operating Voltage | AC 380V±10% 50NZ |
| Specimen Size | Width 300mm* Height 300mm |
| Warranty | 1 Year |
|---|---|
| Power | Hydraulic |
| INSIDE FURNACES DIMENSION | Length 4.0m X Width 3.0m X Height 1.5m |
| Furnace Shell Material | Q235 Steel, Thickness>3mm |
| Smoke Exhaust Fan | 304 Stainless Steel |
| Power | 2KW, Electronic |
|---|---|
| Voltage | 380V, 380v |
| Product Name | Small-scale Test Furnace For Fireproof Coating Of Steel Structure |
| Standard | GB/T9978.1-2008 GB/T14907-2018 GBJ17-2003 GB/T14907-2018 |
| Power | 10kw |
| Refractory Test Furnace | It Is A Vertical Test Furnace |
|---|---|
| Furnace Structure; | The Steel Structure Frame Is Adopted |
| Fluctuation Pressure | ≤ 2% |
| Linearity | <±0.1% O2 |
| Power Consumption | 3kw |
| Working Power Supply | AC 380V ±10%, 50Hz; Power Consumption: 3kW |
|---|---|
| Furnace Pressure Measurement Range | 0–100Pa, Measurement Accuracy: ≤ ±3Pa |
| Air Flow Range 0–50m³/min, Measurement Accuracy | ≤ ±0.5m³/min |
| Combustion Gas Source | Propane, Liquefied Petroleum Gas |
| Gas Flow Range | 0–100L/min, Measurement Accuracy: Class 2.5 |
| Outer Side | Wrapped In Color Steel |
|---|---|
| Internal Dimensions | 4.5m (l) *3.5m (d) *4.25m (h) |
| Furnace Structure | Steel Structure Framec |
| Furnace Lining Material Thickness | 65mm |
| Inside The Furnace Wall | High Temperature Resistant Insulation Material |
| Internal Dimensions | 4.5m (l) *3.5m (d) *4.25m (h) |
|---|---|
| Furnace Structure | Steel Structure Framec |
| Inside The Furnace Wall | High Temperature Resistant Insulation Material |
| Furnace Wall Density | Greater Than 1000kgpm ³ |
| Outer Side | Wrapped In Color Steel |
| Working Voltage | AC 380V±10%, 50hz |
|---|---|
| Power Consumption | 3kw |
| Furnace Pressure Measurement Range | 0-100pa Measurement Accuracy: ≤±3pa |
| Air Flow Rate | 0-50m/min Measurement Accuracy: ≤±0.5 M°/min |
| Combustion Gas Source | Propane, Liquefied Gas |
| Combustion Gas Source | Propane And Liquefied Gas With A Purity Of Over 95% (provided By The User) |
|---|---|
| Gas Flow Rate | 0-100L/min, Measurement Accuracy 2.5 Grade |
| Air Flow Rate | 0 To 50m³/min, Measurement Accuracy ≤±0.5m³/min |
| Gas Tank Capacity | ≥50kg×6 |
| Gap Probe | Made In Accordance With The GB/T9978.1 Standard |