| Heat Source | 610mm Long Tube Gas Burner. |
|---|---|
| Temperature Measurement | 2mm Diameter Armored Thermometer |
| Test Flame Temperature And Time | 650 ± 40 ° C-3 Hours/750 ± 40 ° C-3 Hours 950 ± 40 ° C-3 Hours/950 ± 40 ° C-20 Minutes |
| Sample | Not Less Than 1200mm |
| Test Voltage | 200~1000V (adjustable) |
| Match Flames Ignition Source System | Stainless Steel Combustion Tube (OD8 ± 0.1mm,ID6.5 ± 0.1mm,L200 ± 5mm) |
|---|---|
| Flexible Hose | L2.5-3mm,ID7 ± 1mm |
| Timing Range | 0-999S |
| Testing Distance Of The Igniter | Adjustable From 20 To 80 |
| Flow Measurement Range | 10-100m1/min |
| Burner | The Throat Diameter Is Φ0.19±0.02mm, The Length Is 75mm, The Mixed Gas Outlet Hole Diameter Is Φ1.7, And The Air Inlet Hole Is 4×Φ4mm |
|---|---|
| Fixture | It Can Be Adjusted Freely And Is Suitable For Different Samples |
| Flame Height | Adjustable From 10 To 50mm |
| Ignition Time | 0 To 99.99 Seconds |
| Timing Range | 0 To 99.99 Seconds |
| Warranty | 1 Year |
|---|---|
| Customized Support | OEM, ODM, OBM, Software Reengineering |
| Place Of Origin | Guangdong, China |
| Brand Name | CHENGFENG |
| Model Number | CF8348A |
| Packaging Details | Wooden cases |
|---|---|
| Delivery Time | 10 Work Days |
| Payment Terms | T/T,Cash,L/C, Western Union, MoneyGram |
| Supply Ability | 5 units per month |
| Place of Origin | China |
| Warranty | 1 Year |
|---|---|
| Customized Support | OEM, ODM, OBM, Software Reengineering |
| Model Number | CF8348A |
| Power Supply | 380V±50% ,50Hz±2% |
| Temperature Range | 0℃-50℃ |
| Conductivity Meter | Measuring Range: (0 ~ 1×105)μS/cm |
|---|---|
| Digital PH Meter | Accuracy Of 0.02PH |
| Analytical Balance | Accuracy Of 0.1mg |
| Vi. Sampling | 500mg To 1000mg |
| Air Flowmeter | Adjustable From 20mL To 200mL |
| Packaging Details | Wooden cases |
|---|---|
| Delivery Time | 10 Work Days |
| Payment Terms | T/T, Cash.L/C, D/A, D/P, Western Union, MoneyGram |
| Supply Ability | 5 units per month |
| Place of Origin | China |
| Working Environment Temperature | 0℃-50℃ |
|---|---|
| Working Environment Humidity | <80% |
| Power Supply | 380V±50%,50Hz±2% |
| Exhaust Volume | 0.012m³/s To 0.035m³/s (adjustable |
| Timing Value Resolution | 1S Error <1s/n |
| Environmental Temperature | Operating From 10 ℃ To 35 ℃ |
|---|---|
| Natural Gas Supply | The Gas Supply Standard Specified In The Standard Is The Standard Test Gas G112, As Specified In BS 4947 |
| Gas Flow Rate | The Gas Flow Rate Of The Burner Can Be Adjusted From 0 To 5 N/minute |
| Voltage | 230V, 10A |
| Pressure | 1 Kpa |