| Test Range | Room Temperature To 300℃ |
|---|---|
| Number Of Sample Racks | 2, 3, 6 |
| Heater Power | 4KW |
| Maximum Deformation | 1mm |
| Deformation Resolution | 0.005mm |
| Refractory Test Furnace | It Is A Vertical Test Furnace |
|---|---|
| Furnace Structure; | The Steel Structure Frame Is Adopted |
| Fluctuation Pressure | ≤ 2% |
| Linearity | <±0.1% O2 |
| Power Consumption | 3kw |
| The Condensation Humidification System | A Fully Stainless Steel Shallow Surface Evaporation Humidifier |
|---|---|
| Water Supply System | The Humidification Water Supply Adopts Automatic Control |
| Exposure Methods | Moisture Vapor Condensation Exposure, Light Radiation Exposure |
| The Studio Dimensions | DxWxH450X1170X500 |
| Supported Sample Quantity | Approximately 40 Pieces, 150X75 |
| Working Voltage | AC 380V±10%, 50hz |
|---|---|
| Power Consumption | 3kw |
| Furnace Pressure Measurement Range | 0-100pa Measurement Accuracy: ≤±3pa |
| Air Flow Rate | 0-50m/min Measurement Accuracy: ≤±0.5 M°/min |
| Combustion Gas Source | Propane, Liquefied Gas |
| Warranty | 1 Year |
|---|---|
| Customized Support | OEM, ODM, OBM, Software Reengineering |
| Air Cannon Working Pressure | 0.4-0.8MPa |
| Environmental Temperature | -10 ℃~50 ℃ |
| Steel Ball Launch Speed | 39.7m/s |
| Warranty | 1 Year |
|---|---|
| Customized Support | OEM, ODM, OBM, Software Reengineering |
| Air Cannon Working Pressure | 0.4-0.8MPa |
| Environmental Temperature | -10 ℃~50 ℃ |
| Steel Ball Launch Speed | 39.7m/s |
| Measurement Temperature Range | Room Temperature To 300℃ |
|---|---|
| Temperature Control Accuracy | 0.5℃ |
| Hermal Conductivity Measurement Range | 0.001W/(m·K) To 3.0 W/(m·K) |
| Measurement Repeatability | 3% |
| Specimen Size | 00mm×300mm× (5-30) Mm |
| Thermal Conductivity Range | 0.0010 3 W/mk |
|---|---|
| Accuracy | ± 5% |
| Temperature Range Of The Hot Surface | 100-1200 ℃ |
| Calorimetric Temperature Control Method | Constant Temperature Water Bath |
| Calorimetric Plate Dimensions | 75×75 (mm) |
| Thermal Conductivity Range | 0.0010 3 W/mk |
|---|---|
| Accuracy | ± 5% |
| Temperature Range Of The Hot Surface | 100-1200 ℃ |
| Calorimetric Temperature Control Method | Constant Temperature Water Bath |
| Calorimetric Plate Dimensions | 75×75 (mm) |
| Exhaust Port | Changed From Rectangular To Circular, With A Diameter Of 406mm |
|---|---|
| Thermocouple | Diameter 3mm,3 Pieces, Omega |
| Measurement Range | ≥1300℃ |
| Smoke Density Measurement | Installed At A Distance Of 4.9 To 12.2 Meters From The Tunnel Furnace |
| Voltage Measurement Accuracy | ≤ 5% |