| Plastic Testing Equipment | Carbon Black Content Tester |
|---|---|
| Testing Range | 0.01~0.99 |
| Load Resolution | 1/10,000 |
| Paramters | Extrusion Hole 1=2.095±0.005mm |
| Test Time | 6 Hours |
| Testing Range | 0.01~0.99 |
|---|---|
| Transport Package | Wooden Package |
| Temperature Uniformity | ± 0.5 ℃ |
| Chromatography Type | Gas Chromatography |
| Machine Volume | 30*20*80cm |
| Plastic Testing Equipment | Carbon Black Content Tester |
|---|---|
| Chromatography Type | Gas Chromatography |
| Test Time | 6 Hours |
| Application | School, Hosipital, Lab, Factory |
| Maximum Comsuption | < 600W |
| The Drop Height Of The Ball | Adjustable From 0 To 1500mm |
|---|---|
| Ball Drop Control Mode | DC Electromagnetic Control |
| Steel Ball Weights | 110, 200, 225, 535, 360, 1040, 2260g |
| Power Supply | 220V, 50HZ |
| Machine Weight | Approximately 25 Kilograms |
| Ambient Temperature | Operating Temperature 10℃ To 35℃ |
|---|---|
| Gas Flow Rate | The Gas Flow Rate Of The Burner Is Adjustable From 0 To 5 N/ Minute |
| Voltage | 230V, 10A |
| Pressure | 1 Kpa |
| Highlight | BS476-6 fire spread index tester,building materials flame spread tester,fire spread characteristics testing equipment |
| Deformation Gauge | Measurement Accuracy <0.001mm |
|---|---|
| Micrometer | 0.001mm |
| Test Environment Temperature Requirement | 23℃±5℃ |
| The Humidity Requirement For The Test Environment | 50%±5% |
| Power Supply | 220v 50Hz |
| Measurement Range | 20-88 Hra, 20-100HRB, 20-70HRC |
|---|---|
| Maximum Specimen Height | 200mm |
| Initial Test Force | 98.1N/10Kgf |
| Total Test Force | 588.4N/60Kgf, 980.7N/100Kgf, 1471N/150Kgf |
| Total Test Force Holding Time | 10 Seconds |
| Input Voltage | AC 220 V |
|---|---|
| Output Voltage | AC 0-20 KV |
| Electrical Capacity | 1.5 KVA |
| Test Method | Intermittent Arc, Continuous Arc |
| Test Current | 10MA-20MA-30MA-40MA Optional |
| Impact Energy | 0.5, 1.0, 2.0, 4.0, 5.0J |
|---|---|
| Impact Velocity | 2.9m/s |
| Pendulum Pre-lift Angle | 150 Degrees |
| Graduation Value | 1%F.S(J) |
| Impact Blade Circular Angle Radius | R2mm |
| Hot Wire | A Ring With A Diameter Of 4.0mm Is Made Of Nickel/chromium Wire |
|---|---|
| Temperature Measurement Device | 0.5mm Armored Fine Wire Thermocouple, Capable Of Withstanding A High Temperature Of 1050℃ |
| Heating Current | When The Temperature Is 960℃, The Current Is Between 120 And 150A |
| The Force Applied To The Test | 0.8 To 1.2N, And The Indentation Depth Should Be Limited To At Least 7mm |
| Outer Box Material | Mirror-finish Stainless Steel. |