| Warranty | 1 Year |
|---|---|
| Model Number | CF9253 |
| Function | Long-term Pressure And Plastic Pipe And Composite Pipe Burst Test |
| Temperature Control Range | Room Temperature ~ 95 ℃ |
| Pressure Range | 0 ~ 16MPa (arbitrary Setting) |
| Ambient Temperature | Operating Temperature 10℃ To 35℃ |
|---|---|
| Gas Flow Rate | The Gas Flow Rate Of The Burner Is Adjustable From 0 To 5 N/ Minute |
| Voltage | 230V, 10A |
| Pressure | 1 Kpa |
| Packaging Details | Wooden cases |
| Deformation Gauge | Measurement Accuracy <0.001mm |
|---|---|
| Micrometer | 0.001mm |
| Test Environment Temperature Requirement | 23℃±5℃ |
| The Humidity Requirement For The Test Environment | 50%±5% |
| Power Supply | 220v 50Hz |
| Measurement Range | 20-88 Hra, 20-100HRB, 20-70HRC |
|---|---|
| Maximum Specimen Height | 200mm |
| Initial Test Force | 98.1N/10Kgf |
| Total Test Force | 588.4N/60Kgf, 980.7N/100Kgf, 1471N/150Kgf |
| Total Test Force Holding Time | 10 Seconds |
| Input Voltage | AC 220 V |
|---|---|
| Output Voltage | AC 0-20 KV |
| Electrical Capacity | 1.5 KVA |
| Test Method | Intermittent Arc, Continuous Arc |
| Test Current | 10MA-20MA-30MA-40MA Optional |
| Impact Energy | 0.5, 1.0, 2.0, 4.0, 5.0J |
|---|---|
| Impact Velocity | 2.9m/s |
| Pendulum Pre-lift Angle | 150 Degrees |
| Graduation Value | 1%F.S(J) |
| Impact Blade Circular Angle Radius | R2mm |
| Hot Wire | A Ring With A Diameter Of 4.0mm Is Made Of Nickel/chromium Wire |
|---|---|
| Temperature Measurement Device | 0.5mm Armored Fine Wire Thermocouple, Capable Of Withstanding A High Temperature Of 1050℃ |
| Heating Current | When The Temperature Is 960℃, The Current Is Between 120 And 150A |
| The Force Applied To The Test | 0.8 To 1.2N, And The Indentation Depth Should Be Limited To At Least 7mm |
| Outer Box Material | Mirror-finish Stainless Steel. |
| Propane Flowmeter | 1 To 100cm²/min |
|---|---|
| Light Transmittance Resolution | 0.0001% |
| Measurement Accuracy | ±3% |
| Environmental Humidity | Room Temperature -40℃ |
| Air Flowmeter | 5-500cm²/min |
| Pendulum Energy | 5.5J, 11J, 22J |
|---|---|
| Impact Velocity | 3.5m/s |
| Pendulum Lift Angle | 160 |
| Energy Loss | 5.5J<0.005J, 11J<0.011J, 22J<0.022J |
| Packaging Details | Wooden cases |
| Surface Force | 1.0±0.05N |
|---|---|
| Maximum Test Current | 3A |
| Drip Device | The Drip Time Interval Can Be Set Arbitrarily |
| Outer Box Material | Mirror-finish Stainless Steel. |
| Test Chamber Volume | 0.5M³, Depth X Width X Height: 60x 95x 90cm |