| Load Decomposition Degree | 1/100,000 |
|---|---|
| Load Accuracy | ≤0.5% |
| Test Speed | 0.1-500mm/min (can Be Set Arbitrarily On The Computer) |
| Test Stroke | 400, 500 (can Be Increased As Per Customer Requirements) |
| Test Width | 40cm(can Be Widened As Per Customer Requirements) |
| Maximum Test Height | 300-1500mm(adjustable) |
|---|---|
| Maximum Drop Weight | 1kg |
| Minimum Disengagement Height | 300mm |
| Counter | 0-999999 |
| Gas Source Used | ≥0.5MPa |
| The Suction Capacity Of The Air Pump Is | 40L/min To 100L/min |
|---|---|
| The Ventilation Volume Remains Constant | At (85±1) L/min |
| Air Flow Rate | 8L/MIN |
| Sealing Method | End Face Sealing |
| The Range Of The Differential Pressure Sensor Is | 0 To 500PA |
| Uniformity Of Oil Bath Temperature | <1.5℃ |
|---|---|
| Temperature Control Range | Adjustable From Room Temperature To 300℃ |
| Test Oil | Use 2# Lubricating Oil And Insulating Oil |
| Working Power Supply | AC220V/50HZ |
| Power | 1600W |
| Power Supply Voltage | AC220V±10%, 50HZ, Current ≤10A |
|---|---|
| Maximum Operating Power | 1.5KW |
| Temperature Control Range | 300-1000℃ |
| Heating Power | 800-1000W |
| Control Accuracy | Static ±1℃ (maintenance Time Greater Than 2 Minutes) |
| High-temperature Bath Temperature Range | RT To 250℃ |
|---|---|
| The Humidity Range Of The Low-temperature Bath Is | -50℃ To RT |
| Impact Temperature Of The Test Chamber | High Temperature 50-200 |
| Low Temperature | -10℃ To -40℃ |
| Heating Time | RT-250 ℃ For 60 Minutes |
| Temperature Range | RT+10℃ To 50℃ |
|---|---|
| Humidity Range | >95%RH (Actual Humidity Value In The Working Chamber) |
| Temperature Uniformity | ≤2℃ |
| Temperature Fluctuation | ±0.5℃ |
| Gas Generation Method | Cylinder Method |
| Temperature Range | RT Room Temperature To 70℃ |
|---|---|
| Temperature Uniformity | ±1℃ |
| Temperature Fluctuation | ±0.5℃ |
| Humidity Range | 20-98%RH |
| Temperature Deviation | ±3.0%RH (>75%RH), ±5.0%RH (≤75%RH) |
| The Voltage Used By The Equipment Is | AC 220V±10% |
|---|---|
| Frequency | 50Hz±5% |
| Swing Pipe Size | R=1200mm, |
| Swing Pipe Material | SUS304 Stainless Steel (outer Diameter ≥19mm, Wall Thickness ≥2mm) |
| Total Water Flow Rate | IPX3:3.5L/min; IPX4:5.3 L/min |
| Frequency | 50Hz+/-3%. |
|---|---|
| The Input Power Supply For Work Is | 220V+/-10%AC |
| The Control Accuracy Is | Better Than ±1°C |
| The Required Temperature Range Is | From 10°C To 80°C |
| The Accuracy Of The High-voltage Transformer | Should Be ±1%. |