| Burner | The Throat Diameter Is Φ0.19±0.02mm, The Length Is 75mm, The Mixed Gas Outlet Hole Diameter Is Φ1.7, And The Air Inlet Hole Is 4×Φ4mm |
|---|---|
| Fixture | It Can Be Adjusted Freely And Is Suitable For Different Samples |
| Flame Height | Adjustable From 10 To 50mm |
| Ignition Time | 0 To 99.99 Seconds |
| Timing Range | 0 To 99.99 Seconds |
| Packaging Details | Wooden cases |
|---|---|
| Delivery Time | 10 Work Days |
| Payment Terms | T/T,Cash,L/C, Western Union, MoneyGram |
| Supply Ability | 5 units per month |
| Place of Origin | China |
| Warranty | 1 Year |
|---|---|
| Customized Support | OEM, OBM, ODM, Software Reengineering |
| Model Number | CF8349 |
| Standard | IEC60332-3 |
| Keyword | Cable Burning |
| Warranty | 1 Year |
|---|---|
| Customized Support | OEM, ODM, OBM, Software Reengineering |
| Place Of Origin | Guangdong, China |
| Brand Name | CHENGFENG |
| Model Number | CF8341 |
| Power | 500W |
|---|---|
| Voltage | 220V |
| Application | Heat Shrinkable Materials |
| Power Supply | 220v 50Hz |
| Weight | 60kg |
| Temperature | 15-35℃ |
|---|---|
| Relative Humidity | Not More Than 85%R.H |
| Atmospheric Pressure | 86-106Mpa |
| Dielectric Voltage | AC 220V |
| Reactive Power | 3KW |
| Measuring Range | (0-15) Kw/m ² |
|---|---|
| Accuracy Of Heat Flux Meter | ±0.2Kw/m ² |
| Heat Flux Meter Accuracy | <±3% |
| Computer | One Laptop |
| Measurement Accuracy | ±0.3℃ |
| Heat Source | 610mm Long Tube Gas Burner. |
|---|---|
| Temperature Measurement | 2mm Diameter Armored Thermometer |
| Test Flame Temperature And Time | 650 ± 40 ° C-3 Hours/750 ± 40 ° C-3 Hours 950 ± 40 ° C-3 Hours/950 ± 40 ° C-20 Minutes |
| Sample | Not Less Than 1200mm |
| Test Voltage | 200~1000V (adjustable) |
| Match Flames Ignition Source System | Stainless Steel Combustion Tube (OD8 ± 0.1mm,ID6.5 ± 0.1mm,L200 ± 5mm) |
|---|---|
| Flexible Hose | L2.5-3mm,ID7 ± 1mm |
| Timing Range | 0-999S |
| Testing Distance Of The Igniter | Adjustable From 20 To 80 |
| Flow Measurement Range | 10-100m1/min |
| Hot Wire | A Ring With A Diameter Of 4.0mm Is Made Of Nickel/chromium Wire |
|---|---|
| Temperature Measurement Device | 0.5mm Armored Fine Wire Thermocouple, Capable Of Withstanding A High Temperature Of 1050℃ |
| Heating Current | When The Temperature Is 960℃, The Current Is Between 120 And 150A |
| The Force Applied To The Test | 0.8 To 1.2N, And The Indentation Depth Should Be Limited To At Least 7mm |
| Outer Box Material | Mirror-finish Stainless Steel. |