Introduction:
|
The hand-held coating thickness gauge is a portable measuring instrument that can measure the coating or coating thickness
quickly, without damage and with precision. It can be used in the laboratory or in the engineering field. Scope of application:
This instrument adopts magnetic and eddy current thickness measurement methods, which can non-destructively measure non-magnetic metal substrates (such as copper, aluminum. Zinc. tin, etc.), the thickness of the non-conductive covering layer (such as oxide film, enamel, rubber, paint, plastic, etc.) This instrument has the characteristics of small measurement error, high reliability, good stability, and easy operation. Hand-held coating thickness gauge: widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields. It is a must-have instrument for material protection |
|
Instrument features:
|
Small design, easy to carry.
Fully intelligent design, easy to operate. Fast measurement and good repeatability. Zero-point calibration, two-point calibration. Single and continuous measurements LCD digital display There is a beep prompt during operation Deletion of a single suspicious data that appears in the measurement Two probe designs for different testing sites It has the function of power supply under-voltage indication A power charger is included, and two rechargeable batteries are included It has an automatic shutdown function |
|
Main technical indicators:
|
Ambient temperature: 0~40°C
Power supply: 9V*1 Statistical functions (single measurement): average, maximum, minimum, number of measurements Minimum substrate: 10*10mm Minimum curvature: convex 5mm; Concave 25mm Thinnest body: 0.5mm Dimensions: 125×74×33 Weight: 280G Measuring range: 0--1000μm (optional) Measurement accuracy: zero point calibration, +(3%h+1.5) two-point calibration: +(1%-3%)H+1.5 Display accuracy: 0.1 |
|
Main functions of hand-held coating thickness gauge:
|
There are two calibration methods: one-point calibration and two-point calibration.
Basic calibration resolution: 0.1 μm (measurement range less than 100 μm) 1 μm (measuring range > 100 μm) There are five statistics and 459 data are stored There are two types of measurement: continuous measurement and single measurement There are two shutdown methods: manual shutdown and automatic shutdown Configurable limit: The measured value outside the limit can be automatically alarmed, and a batch of measured values can be analyzed with a histogram; Delete function: Gross errors and wrong settings can be deleted; There is a power supply undervoltage indication function It can work while charging Error prompt function Basic configuration of hand-held coating thickness gauge:
1 host 1 N1 probe Calibration standard 1 box 2 batteries |