I. Scope of Application
It is applicable to the torsion resistance test of twisted flexible cables used in wind power generation systems or similar systems with a rated voltage of 1.8/3kV and below in low-temperature environments.
Ii. Compliance with Standards
TICW1-2009 Test Method for Torsion of Wind Power Generation Torsion-Resistant Flexible Cables
GB/T2423.1-2001 Test A: Low Temperature Test Method, GB/T2423.2-2001 Test B: High Temperature Test Method.
Iii. Technical Parameters
Studio dimensions: 400×300×2300mm;
Test channel: 300 × 300 × 12600 mm;
External dimensions: 1550×2500mm
Left height: 1720mm;
Right height: 9620mm;
The external dimensions of the left and right channels: 640×54mm;
Total mass: approximately 2,500 kg;
Cable testing range: Testing of wind energy cables below 35KV;
Temperature range: -60 to 8 ℃
Temperature fluctuation: ≤ ± 0.5 ℃
Temperature uniformity: ≤ ± 0.3 ℃
Heating time: Adjustable;
Cooling time: Average 0.7 to 1.0 ℃ /min;
Observation window: Multi-layer hollow, high-temperature resistant (500 ℃);
Glass window: (200 × 300) Twisted control cabinet, frame: 700 × 1300 × 1400;
Door opening: Single-hinged door;
Control panel: Power supply, controller display screen, control buttons;
Distribution control cabinet: distribution board, exhaust fan;
Heater: Stainless steel finned heater;
Fixture: One set of cable torsion fixture;
Power cord hole and drainage hole: Located on the back of the box.