Compliance with standards: Complies with the test standard requirements of GB/T11835 "Test Method for Thermal Load Shrinkage Temperature of Mineral Wool and Products".
Product Overview: Suitable for rock wool, slag wool and glass wool and their products, not suitable for aluminosilicate wool and its products. Under a fixed load, the sample is heated at a certain heating rate to reach the specified thickness shrinkage rate. Through calculation, the thermal load shrinkage temperature is obtained by interpolation
Technical Specifications:
Composed of a heating furnace, a heating container, and a temperature sensor.
Environmental temperature: room temperature~40 ℃
Relative humidity: ≤ 75%
Working voltage: AC 220V ± 10V 50Hz
Heating power: 3500W
Scaling measurement range: room temperature~900 ℃
Heating rate: 5 ℃/min ± 0.3 ℃ and 3 ℃/min ± 0.2 ℃ can be set
The instrument adopts a single-chip computer and a multi-point program for temperature rise.
The heat source adopts a hot plate type, which is safe and reliable, and has a long service life
The instrument is equipped with a surface layout printer, which can print test results in a timely manner.
Implementation method: Use a microcontroller or PLC temperature control module to achieve
Working voltage: AC 220V
Heating rate: The heating rate is divided into two stages, normal temperature~700 ℃ and 700~900 ℃; And the heating rate and maximum temperature can be set, with an error of min ± 0.2 ℃.
Thermocouple: K-type
Heating furnace: Made of ceramic fibers, resistant to chemical corrosion and high temperature. It can be used for a long time at 1600 ℃, with a short-term temperature of 1800 ℃. It is resistant to sudden cooling and heating, not easy to explode, and is formed by injection molding with high density.
External insulation layer: using fire-resistant conversion
Heating furnace wire: nickel 80 chromium 20 alloy wire, temperature resistant to 1350 degrees
External dimensions: 1000 * 400 * 1000 length, width, and height
Installation environment:
Required installation space: 1000 x 600 x 1000mm (length x width x height)
Power supply: 220V/50/50HZ, power above 2200W
Exhaust: It is required to perform exhaust treatment on samples with heat generation
Surrounding environment requirements: Keep away from flammable and explosive materials, as well as corrosive liquids and gases
Working environment: 20 ℃ -40 ℃
Voltage: 220V 50Hz 3.5KW
Temperature controlled heating: 0-800 ℃
Heating rate: (50 ℃ -450 ℃) 5 ℃/min; (450 ℃ -800 ℃) 3 ℃/min
Test pressure: 490Pa