| Test Range | Room Temperature To 300℃ |
|---|---|
| Heater Power | 4KW; |
| Vicat Deflection | 1mm. |
| Deformation Resolution Error | 0.005mm |
| Heating Rate | A=5℃/6min, B=12℃/6min; |
| Maximum Operating Power | 0.5KW |
|---|---|
| Power Supply Voltage | AC220V±10%, 50Hz |
| Auxiliary Burner Pressure | 138KPa (adjustable) |
| Accuracy Of Smoke Density Measurement | ±3% |
| Smoke Density Measurement Range | 0 To 100% |
| Total Calorific Value Of Combustion | 30,000,000 J/Kg(30MJ/kg) |
|---|---|
| Repeatability Error Of Combustion Calorific Value | Dynamic ≤0.1% |
| Temperature Measurement Range | 0 To 50℃ |
| Heat Capacity Accuracy | ≤0.1% |
| Heat Capacity Stability | ≤0.2% |
| Uniformity Of Oil Bath Temperature | <1.5℃ |
|---|---|
| Temperature Control Range | Adjustable From Room Temperature To 300℃ |
| Power | 1600W |
| Test Oil | Use 2# Lubricating Oil And Insulating Oil |
| Time Control | 0 To 999 Hours And 99 Minutes. |
| Accuracy Of The Heat Flux Meter | ±0.2Kw/m ² |
|---|---|
| Heat Flux Meter Accuracy | <±3% |
| Accuracy | Of ±0.5℃ |
| Blackbody Temperature Error | ±5℃ |
| Smoke Exhaust Velocity | (2.5±0.2)m/s |
| Horizontal Combustion Ignition Time | 60 Seconds |
|---|---|
| Vertical Combustion Ignition Time | 10 Seconds |
| Vertical Burning Weighing Pan | Aluminum, Diameter 50mm |
| Vertical Burning Flame Height | 25 To 30mm |
| Vertical Combustion Sample Position | 25mm From The Center Of The Top Of The Combustion Tube |
| Test Station | 1 Station |
|---|---|
| Fuel | Chemically Pure Anhydrous Ethanol |
| The Dimensions Of The Combustion Chamber Are | 340mm× 230mm × 794mm |
| Combustion Lamp | Made Of Brass, Outer Diameter 24mm, Wall Thickness 1mm, Height 17mm |
| Packaging Details | Wooden cases |
| Nozzle Inner Diameter | 9.6mm; |
|---|---|
| Air Supply Mode | Automatic Air Supply By The Fan, Air Supply Time: 60 Seconds. |
| Supply Air Velocity | 1.5M/S; |
| Electronic Anemometer | Test Range 0 To 8M/S |
| TES Thermometer | Measuring Range 0 To 1300℃, Accuracy 0.1℃ |
| Heating Rate | 5 ℃ /min Or 3 ℃ /min Can Be Set. |
|---|---|
| Temperature Collection | Collected Every 2 Minutes And Displayed With A Curve; |
| Thermocouple Response Time | <0.5 Seconds |
| Temperature Error | ± 0.5 ℃ |
| Timing Error | 1 Second /h |
| Voltage Stabilizer | 2KVA, Voltage Stability ≤±1% |
|---|---|
| Timing Range | 0 To 99 Hours, Accuracy ±1 Second |
| Power Supply Voltage | AC220V±10%, 50Hz, Current ≤10A |
| Heating Power | 800-1000W; |
| Packaging Details | Wooden cases |