| Horizontal Combustion Ignition Time | 60 Seconds |
|---|---|
| Vertical Combustion Ignition Time | 10 Seconds |
| Vertical Burning Weighing Pan | Aluminum, Diameter 50mm |
| Vertical Burning Flame Height | 25 To 30mm |
| Vertical Combustion Sample Position | 25mm From The Center Of The Top Of The Combustion Tube |
| Test Station | 1 Station |
|---|---|
| Fuel | Chemically Pure Anhydrous Ethanol |
| The Dimensions Of The Combustion Chamber Are | 340mm× 230mm × 794mm |
| Combustion Lamp | Made Of Brass, Outer Diameter 24mm, Wall Thickness 1mm, Height 17mm |
| Highlight | fireproof coating tester small chamber,combustion tester GB/T 12441-2005,fire testing equipment with warranty |
| Nozzle Inner Diameter | 9.6mm; |
|---|---|
| Air Supply Mode | Automatic Air Supply By The Fan, Air Supply Time: 60 Seconds. |
| Supply Air Velocity | 1.5M/S; |
| Electronic Anemometer | Test Range 0 To 8M/S |
| TES Thermometer | Measuring Range 0 To 1300℃, Accuracy 0.1℃ |
| Voltage Stabilizer | 2KVA, Voltage Stability ≤±1% |
|---|---|
| Timing Range | 0 To 99 Hours, Accuracy ±1 Second |
| Power Supply Voltage | AC220V±10%, 50Hz, Current ≤10A |
| Heating Power | 800-1000W; |
| Highlight | UL 1685 cable flame test apparatus,wire combustion testing equipment,bundled cable flame suppression tester |
| Sample Rack Mass | 15g+1g |
|---|---|
| Voltage Stabilizer | 2KVA, Voltage Stability ≤±1% |
| Thermometer | 0 To 1000±2% |
| Timing Range | 0 To 99 Hours, Accuracy ±1 Second |
| Power Supply Voltage | AC220V±10%, 50Hz, Current ≤10A |
| Power Supply Voltage | AC220V±10%, 50Hz; |
|---|---|
| Gas Pressure | 10kpa To 50kpa; |
| The Accuracy Is | ±0.1m/s. |
| Flame Release Time | 0 To 99 Minutes And 99 Seconds Can Be Set. |
| Burning Duration | 0 To 99 Minutes And 99 Seconds Can Be Set. |
| Combustion Gas Source | Propane And Liquefied Gas With A Purity Of Over 95% (provided By The User) |
|---|---|
| Gas Flow Rate | 0-100L/min, Measurement Accuracy 2.5 Grade |
| Air Flow Rate | 0 To 50m³/min, Measurement Accuracy ≤±0.5m³/min |
| Gas Tank Capacity | ≥50kg×6 |
| Gap Probe | Made In Accordance With The GB/T9978.1 Standard |
| Signal Output | 4-20mA |
|---|---|
| Response Time T90 | ≤2 Seconds |
| Ambient Temperature | 0-45℃ |
| Relative Humidity | <90% (no Condensation) |
| Linearity | <± 0.1%O2 |
| Timer Resolution | 0.1S, Error No More Than 1s/h |
|---|---|
| Fuel Flowmeter | Adjustable From 35 To 350L/H, Control Accuracy ±2L/h |
| Fuel Consumption Control Accuracy | 565±2g/50min |
| Power Supply Voltage | AC380V 50Hz Three-phase Five-wire System; |
| Power Consumption | 4.01KW |
| Supply Voltage And Power | 220V±10%, 50HZ, Power Approximately 100W |
|---|---|
| The Inner Diameter Of The Bunsen Burner Is | 10mm±0.10mm |
| Gas Source | Methane, Propane, Butane, Liquefied Petroleum Gas |
| Ambient Temperature | -10 ℃ To 30℃ |
| Relative Humidity | ≤85% |