| Test Station | 1 Station |
|---|---|
| Fuel | Chemically Pure Anhydrous Ethanol |
| The Dimensions Of The Combustion Chamber Are | 340mm× 230mm × 794mm |
| Combustion Lamp | Made Of Brass, Outer Diameter 24mm, Wall Thickness 1mm, Height 17mm |
| Packaging Details | Wooden cases |
| Nozzle Inner Diameter | 9.6mm; |
|---|---|
| Air Supply Mode | Automatic Air Supply By The Fan, Air Supply Time: 60 Seconds. |
| Supply Air Velocity | 1.5M/S; |
| Electronic Anemometer | Test Range 0 To 8M/S |
| TES Thermometer | Measuring Range 0 To 1300℃, Accuracy 0.1℃ |
| Heating Rate | 5 ℃ /min Or 3 ℃ /min Can Be Set. |
|---|---|
| Temperature Collection | Collected Every 2 Minutes And Displayed With A Curve; |
| Thermocouple Response Time | <0.5 Seconds |
| Temperature Error | ± 0.5 ℃ |
| Timing Error | 1 Second /h |
| Voltage Stabilizer | 2KVA, Voltage Stability ≤±1% |
|---|---|
| Timing Range | 0 To 99 Hours, Accuracy ±1 Second |
| Power Supply Voltage | AC220V±10%, 50Hz, Current ≤10A |
| Heating Power | 800-1000W; |
| Packaging Details | Wooden cases |
| Sample Rack Mass | 15g+1g |
|---|---|
| Voltage Stabilizer | 2KVA, Voltage Stability ≤±1% |
| Thermometer | 0 To 1000±2% |
| Timing Range | 0 To 99 Hours, Accuracy ±1 Second |
| Power Supply Voltage | AC220V±10%, 50Hz, Current ≤10A |
| Power Supply Voltage | AC220V±10%, 50Hz; |
|---|---|
| Gas Pressure | 10kpa To 50kpa; |
| The Accuracy Is | ±0.1m/s. |
| Flame Release Time | 0 To 99 Minutes And 99 Seconds Can Be Set. |
| Burning Duration | 0 To 99 Minutes And 99 Seconds Can Be Set. |
| Combustion Gas Source | Propane And Liquefied Gas With A Purity Of Over 95% (provided By The User) |
|---|---|
| Gas Flow Rate | 0-100L/min, Measurement Accuracy 2.5 Grade |
| Air Flow Rate | 0 To 50m³/min, Measurement Accuracy ≤±0.5m³/min |
| Gas Tank Capacity | ≥50kg×6 |
| Gap Probe | Made In Accordance With The GB/T9978.1 Standard |
| Signal Output | 4-20mA |
|---|---|
| Response Time T90 | ≤2 Seconds |
| Ambient Temperature | 0-45℃ |
| Relative Humidity | <90% (no Condensation) |
| Linearity | <± 0.1%O2 |
| Heating Rate | 5 ℃ /min Or 3 ℃ /min Can Be Set |
|---|---|
| Temperature Collection | Collected Every 2 Minutes And Displayed With A Curve |
| Thermocouple Response Time | <0.5 Seconds |
| Temperature Error | ± 0.5 ℃ |
| Timing Error | 1 Second /h |
| Gas Flow Rate | 0-100L/min, Measurement Accuracy 2.5 Grade |
|---|---|
| Air Flow Rate | 0-50m ³ /min, Measurement Accuracy ≤±0.5m ³ /min. |
| Gas Tank Capacity | ≥50kg×6 |
| Load Measurement Equipment | ±2.5% Of The Load Value Should Be Added |
| Furnace Pressure Measurement Range | 0 To 100pa |